Journal of chromatography. A 2014-11-21

High-throughput hydrophilic interaction chromatography coupled to tandem mass spectrometry for the optimized quantification of the anti-Gram-negatives antibiotic colistin A/B and its pro-drug colistimethate.

Thomas Mercier, Fréderic Tissot, Céline Gardiol, Natascia Corti, Stéphane Wehrli, Monia Guidi, Chantal Csajka, Thierry Buclin, William Couet, Oscar Marchetti, Laurent A Decosterd

Index: J. Chromatogr. A. 1369 , 52-63, (2014)

Full Text: HTML

Abstract

Colistin is a last resort's antibacterial treatment in critically ill patients with multi-drug resistant Gram-negative infections. As appropriate colistin exposure is the key for maximizing efficacy while minimizing toxicity, individualized dosing optimization guided by therapeutic drug monitoring is a top clinical priority. Objective of the present work was to develop a rapid and robust HPLC-MS/MS assay for quantification of colistin plasma concentrations. This novel methodology validated according to international standards simultaneously quantifies the microbiologically active compounds colistin A and B, plus the pro-drug colistin methanesulfonate (colistimethate, CMS). 96-well micro-Elution SPE on Oasis Hydrophilic-Lipophilic-Balanced (HLB) followed by direct analysis by Hydrophilic Interaction Liquid Chromatography (HILIC) with Ethylene Bridged Hybrid--BEH--Amide phase column coupled to tandem mass spectrometry allows a high-throughput with no significant matrix effect. The technique is highly sensitive (limit of quantification 0.014 and 0.006 μg/mL for colistin A and B), precise (intra-/inter-assay CV 0.6-8.4%) and accurate (intra-/inter-assay deviation from nominal concentrations -4.4 to +6.3%) over the clinically relevant analytical range 0.05-20 μg/mL. Colistin A and B in plasma and whole blood samples are reliably quantified over 48 h at room temperature and at +4°C (<6% deviation from nominal values) and after three freeze-thaw cycles. Colistimethate acidic hydrolysis (1M H2SO4) to colistin A and B in plasma was completed in vitro after 15 min of sonication while the pro-drug hydrolyzed spontaneously in plasma ex vivo after 4 h at room temperature: this information is of utmost importance for interpretation of analytical results. Quantification is precise and accurate when using serum, citrated or EDTA plasma as biological matrix, while use of heparin plasma is not appropriate. This new analytical technique providing optimized quantification in real-life conditions of the microbiologically active compounds colistin A and B offers a highly efficient tool for routine therapeutic drug monitoring aimed at individualizing drug dosing against life-threatening infections.Copyright © 2014 Elsevier B.V. All rights reserved.

Related Compounds

Structure Name/CAS No. Articles
Formic Acid Structure Formic Acid
CAS:64-18-6
Sodium hydroxide Structure Sodium hydroxide
CAS:1310-73-2
Acetonitrile Structure Acetonitrile
CAS:75-05-8
Methanol Structure Methanol
CAS:67-56-1
Formic acid ammonium salt Structure Formic acid ammonium salt
CAS:540-69-2
3-Ethyl-2,4-pentanedione Structure 3-Ethyl-2,4-pentanedione
CAS:1540-34-7
Colistin methanesulfonate sodium salt Structure Colistin methanesulfonate sodium salt
CAS:8068-28-8