Bryan J McCullough, Tony Bristow, Gavin O'Connor, Chris Hopley
Index: Rapid Commun. Mass Spectrom. 25(10) , 1445-51, (2011)
Full Text: HTML
The design and development of a novel extractive electrospray ionisation (EESI) device for on-line reaction monitoring is described. The EESI apparatus uses a secondary, grounded nebuliser to produce an analyte aerosol and a Venturi pump is then used to transfer a sample of the aerosol to an electrospray source where it is ionised. The EESI apparatus was then tested with a variety of small, organic molecules to assess sensitivity, linearity and dynamic range. The performance of the technique will depend on the mass spectrometer used for the experiments; in the configurations used here it has a usable dynamic range of around 3.5 orders of magnitude with a linear range of around 2.5 orders of magnitude and is capable of analysing species present down to low µg/mL with signal-to-noise ratio greater than 2.5. The use of EESI for reaction monitoring was validated using a series of mock reaction mixtures and then used to monitor the base hydrolysis of ethyl salicylate to salicylic acid.Copyright © 2011 John Wiley & Sons, Ltd.
| Structure | Name/CAS No. | Molecular Formula | Articles | 
|---|---|---|---|
                        ![]()  | 
                    Ethyl salicylate
                     CAS:118-61-6  | 
                    C9H10O3 | 
| 
                                
                                Evaluation of injection methods for fast, high peak capacity...
                                 2015-05-01 [J. Chromatogr. A. 1392 , 82-90, (2015)]  | 
                        
| 
                                
                                Occurrence and spatial distribution of EDCs and related comp...
                                 2015-01-15 [Sci. Total Environ. 503-504 , 69-86, (2015)]  | 
                        
| 
                                
                                Analysis of endocrine disrupters and related compounds in se...
                                 2014-07-25 [J. Chromatogr. A. 1352 , 29-37, (2014)]  | 
                        
| 
                                
                                Encapsulation of methyl and ethyl salicylates by beta-cyclod...
                                 2008-11-04 [J. Pharm. Biomed. Anal. 48(3) , 969-73, (2008)]  | 
                        
| 
                                
                                Optimization and validation of liquid chromatography and hea...
                                 2012-02-23 [J. Pharm. Biomed. Anal. 60 , 51-8, (2012)]  | 
                        
Home | MSDS/SDS Database Search | Journals | Product Classification | Biologically Active Compounds | Selling Leads | About Us | Disclaimer
Copyright © 2024 ChemSrc All Rights Reserved