![]() Ethyl salicylate structure
|
Common Name | Ethyl salicylate | ||
---|---|---|---|---|
CAS Number | 118-61-6 | Molecular Weight | 166.174 | |
Density | 1.2±0.1 g/cm3 | Boiling Point | 234.4±13.0 °C at 760 mmHg | |
Molecular Formula | C9H10O3 | Melting Point | 1 °C(lit.) | |
MSDS | Chinese USA | Flash Point | 107.2±0.0 °C | |
Symbol |
![]() GHS07 |
Signal Word | Warning |
Evaluation of injection methods for fast, high peak capacity separations with low thermal mass gas chromatography.
J. Chromatogr. A. 1392 , 82-90, (2015) Low thermal mass gas chromatography (LTM-GC) was evaluated for rapid, high peak capacity separations with three injection methods: liquid, headspace solid phase micro-extraction (HS-SPME), and direct vapor. An Agilent LTM equipped with a short microbore capil... |
|
Occurrence and spatial distribution of EDCs and related compounds in waters and sediments of Iberian rivers.
Sci. Total Environ. 503-504 , 69-86, (2015) The environmental presence of chemicals capable of affecting the endocrine system has become a matter of scientific and public concern after certain endocrine disruptor compounds (EDCs) have been detected in the aquatic environment. In this work, 31 different... |
|
Analysis of endocrine disrupters and related compounds in sediments and sewage sludge using on-line turbulent flow chromatography-liquid chromatography-tandem mass spectrometry.
J. Chromatogr. A. 1352 , 29-37, (2014) A novel fully automated method based on dual column switching using turbulent flow chromatography followed by liquid chromatography coupled to tandem mass spectrometry (TFC-LC-MS/MS) was applied for the determination of endocrine disruptors (EDCs) and related... |
|
On-line reaction monitoring by extractive electrospray ionisation.
Rapid Commun. Mass Spectrom. 25(10) , 1445-51, (2011) The design and development of a novel extractive electrospray ionisation (EESI) device for on-line reaction monitoring is described. The EESI apparatus uses a secondary, grounded nebuliser to produce an analyte aerosol and a Venturi pump is then used to trans... |
|
Encapsulation of methyl and ethyl salicylates by beta-cyclodextrin HPLC, UV-vis and molecular modeling studies.
J. Pharm. Biomed. Anal. 48(3) , 969-73, (2008) The complexation of methyl salicylate (MS) and ethyl salicylate (ES), non-steroidal analgesic, anti-inflammatory and antirrheumatic drugs with beta-cyclodextrin (betaCD) has been studied from thermodynamic and structural points of view. The complexation with ... |
|
Optimization and validation of liquid chromatography and headspace-gas chromatography based methods for the quantitative determination of capsaicinoids, salicylic acid, glycol monosalicylate, methyl salicylate, ethyl salicylate, camphor and l-menthol in a topical formulation.
J. Pharm. Biomed. Anal. 60 , 51-8, (2012) Capsaicinoids, salicylic acid, methyl and ethyl salicylate, glycol monosalicylate, camphor and l-menthol are widely used in topical formulations to relieve local pain. For each separate compound or simple mixtures, quantitative analysis methods are reported. ... |
|
Levels of mint and wintergreen flavorants: smokeless tobacco products vs. confectionery products.
Food Chem. Toxicol. 48(2) , 755-63, (2010) Nicotine and flavorant compound levels were measured in 10 "mint"-related sub-brands and 8 "wintergreen" sub-brands of smokeless tobacco (SLT). Also analyzed were "mint"-related and "wintergreen" confectionery products. Of the "mint" SLT, "Timberwolf Packs Mi... |
|
Simultaneous quantitative analysis of methyl salicylate, ethyl salicylate and salicylic acid from biological fluids using gas chromatography-mass spectrometry.
J. Chromatogr. B. Biomed. Sci. Appl. 718(1) , 69-75, (1998) A gas chromatographic-mass spectrometric (GC-MS) assay was developed for the quantitative analysis of methyl salicylate (MeS), ethyl salicylate (ES) and salicylic acid (SA) from biological fluids. The method was validated from 100-microl rat liver homogenate ... |
|
Percutaneous penetration and skin metabolism of ethylsalicylate-containing agent, TU-2100: in-vitro and in-vivo evaluation in guinea pigs.
J. Control. Release 79(1-3) , 113-22, (2002) The aim of this study was to investigate the percutaneous penetration and dermal metabolism of a new potential anti-acne prodrug--TU-2100 [bis(o-carboxyphenyl ethyl ester)nonanedioate] in guinea pigs. The fluxes of this agent through excised skin after applic... |
|
Some observations on the pharmacology of 'deep-heat', a topical rubifacient.
Ann. Rheum. Dis. 43(3) , 411-5, (1984) A topically applied rubifacient delivered by aerosol (Deep-Heat) was studied. After spray application to the forearms of volunteers, without massage, the erythema produced was measured by thermography and correlated with the concentration of 2 salicylate comp... |