Top Suppliers:I want be here


189639-09-6

189639-09-6 structure
189639-09-6 structure
  • Name: 9-CP-Ade mesylate
  • Chemical Name: 9-Cyclopentyladenine monomethanesulfonate
  • CAS Number: 189639-09-6
  • Molecular Formula: C11H17N5O3S
  • Molecular Weight: 299.34900
  • Catalog: Signaling Pathways GPCR/G Protein Adenylate Cyclase
  • Create Date: 2018-03-28 08:00:00
  • Modify Date: 2024-01-15 13:16:42
  • 9-Cyclopentyladenine monomethylsulfonate (9-CP-Ade mesylate) is a stable non-competitive adenylate cyclase inhibitor with cell permeable properties[1][2].

Name 9-Cyclopentyladenine monomethanesulfonate
Synonyms 9-cyclopentylpurin-6-amine,methanesulfonic acid
9-CP-Ade mesylate 9-Cyclopentyladenine mesylate
Description 9-Cyclopentyladenine monomethylsulfonate (9-CP-Ade mesylate) is a stable non-competitive adenylate cyclase inhibitor with cell permeable properties[1][2].
Related Catalog
In Vitro 9-Cyclopentyladenine monomethanesulfonate (200 μM, 30 min) inhibits the activation of cAMP response element binding protein (CREB) and completely blocks neurogenesis in PC12 cells[1]. 9-Cyclopentyladenine monomethanesulfonate (100 μM, 30min) attenuates the effect of relaxin on mechanical activity and prevents relaxin-induced hyperpolarization thereby being involved in the regulation of relaxin on ileal smooth muscle activity in female CD1 Swiss mice[2]. 9-Cyclopentyladenine monomethanesulfonate (100 μM, 6 hours) promotes restoration of the keratinocyte permeability barrier by inhibiting the synthesis of cAMP in male hairless mice[3].
References

[1]. Ulrike Riese,et al. Militarinone A induces differentiation in PC12 cells via MAP and Akt kinase signal transduction pathways. FEBS Lett. 2004 Nov 19;577(3):455-9.

[2]. Eglantina Idrizaj,et al. Relaxin influences ileal muscular activity through a dual signaling pathway in mice. World J Gastroenterol. 2018 Feb 28;24(8):882-893.

[3]. Mitsuhiro Denda, et al. Association of cyclic adenosine monophosphate with permeability barrier homeostasis of murine skin. J Invest Dermatol. 2004 Jan;122(1):140-6.

Boiling Point 440.5ºC at 760 mmHg
Melting Point 180-183ºC(lit.)
Molecular Formula C11H17N5O3S
Molecular Weight 299.34900
Flash Point 220.2ºC
Exact Mass 299.10500
PSA 132.37000
LogP 2.68960
Vapour Pressure 5.85E-08mmHg at 25°C

Section1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE
Product identifiers
Product name: 9-Cyclopentyladenine monomethanesulfonate
CAS-No.: 189639-09-6
Relevant identified uses of the substance or mixture and uses advised against
Identified uses: Laboratory chemicals, Manufacture of substances



Section2. HAZARDS IDENTIFICATION
Classification of the substance or mixture
Not a hazardous substance or mixture according to Regulation (EC) No 1272/2008
This substance is not classified as dangerous according to Directive 67/548/EEC.
Label elements
Caution - substance not yet tested completely.
Other hazards - none

Section3. COMPOSITION/INFORMATION ON INGREDIENTS
Substances
Synonyms: 9-CP-Ademesylate
9-Cyclopentyladeninemesylate
Formula: C10H13N5 · CH4O3S
Molecular Weight: 299,35 g/mol

Section4. FIRST AID MEASURES
Description of first aid measures
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration.
In case of skin contact
Wash off with soap and plenty of water.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water.
Most important symptoms and effects, both acute and delayed
Indication of any immediate medical attention and special treatment needed
no data available

Section5. FIREFIGHTING MEASURES
Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Carbon oxides, nitrogen oxides (NOx), Sulphur oxides
Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
no data available

Section6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Avoid dust formation. Avoid breathing vapors, mist or gas.
Environmental precautions
Do not let product enter drains.
Methods and materials for containment and cleaning up
Sweep up and shovel. Keep in suitable, closed containers for disposal.
Reference to other sections
For disposal see section 13.

Section7. HANDLING AND STORAGE
Precautions for safe handling
Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire
protection.
Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Specific end uses
no data available

Section8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Components with workplace control parameters
Exposure controls
Appropriate engineering controls
General industrial hygiene practice.
Personal protective equipment
Eye/face protection
Use equipment for eye protection tested and approved under appropriate government standards
such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and
the standard EN 374 derived from it.
Body Protection
Choose body protection in relation to its type, to the concentration and amount of dangerous
substances, and to the specific work-place., The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Respiratory protection is not required. Where protection from nuisance levels of dusts are desired,
use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and
approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Section9. PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
a) AppearanceForm: solid
b) Odourno data available
c) Odour Thresholdno data available
d) pHno data available
e) Melting point/freezingMelting point/range: 180 - 183 °C
point
f) Initial boiling point and no data available
boiling range
g) Flash pointno data available
h) Evaporation rateno data available
i) Flammability (solid, gas) no data available
j) Upper/lowerno data available
flammability or
explosive limits
k) Vapour pressureno data available
l) Vapour densityno data available
m) Relative densityno data available
n) Water solubilityno data available
o) Partition coefficient: n- no data available
octanol/water
p) Autoignitionno data available
temperature
q) Decompositionno data available
temperature
r) Viscosityno data available
s) Explosive propertiesno data available
t) Oxidizing propertiesno data available
Other safety information
no data available

Section10. STABILITY AND REACTIVITY
Reactivity
no data available
Chemical stability
no data available
Possibility of hazardous reactions
no data available
Conditions to avoid
no data available
Incompatible materials
Strong oxidizing agents
Hazardous decomposition products
Other decomposition products - no data available

Section11. TOXICOLOGICAL INFORMATION
Information on toxicological effects
Acute toxicity
LD50 Intravenous - mouse - 50 mg/kg
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
IARC:No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Potential health effects
Inhalation
May be harmful if inhaled. May cause respiratory tract irritation.
IngestionMay be harmful if swallowed.
SkinMay be harmful if absorbed through skin. May cause skin irritation.
EyesMay cause eye irritation.
Additional Information
RTECS: Not available

Section12. ECOLOGICAL INFORMATION
Toxicity
no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Results of PBT and vPvB assessment
no data available
Other adverse effects
no data available

Section13. DISPOSAL CONSIDERATIONS
Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company.
Contaminated packaging
Dispose of as unused product.

Section14. TRANSPORT INFORMATION
UN number
ADR/RID: -IMDG: -IATA: -
UN proper shipping name
ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA:Not dangerous goods
Transport hazard class(es)
ADR/RID: -IMDG: -IATA: -
Packaging group
ADR/RID: -IMDG: -IATA: -
Environmental hazards
ADR/RID: noIMDG Marine pollutant: noIATA: no
Special precautions for user
no data available



SECTION 15 - REGULATORY INFORMATION
N/A


SECTION 16 - ADDITIONAL INFORMATION
N/A
Personal Protective Equipment Eyeshields;Gloves;type N95 (US);type P1 (EN143) respirator filter
RIDADR NONH for all modes of transport
RTECS AU6255000