2905-67-1

2905-67-1 structure
2905-67-1 structure
  • Name: 3,5-dichlorobenzoic acid methyl ester
  • Chemical Name: methyl 3,5-dichlorobenzoate
  • CAS Number: 2905-67-1
  • Molecular Formula: C8H6Cl2O2
  • Molecular Weight: 205.03800
  • Create Date: 2018-04-02 08:00:00
  • Modify Date: 2024-01-04 20:08:16

Name methyl 3,5-dichlorobenzoate
Synonyms MFCD00032710
3,5-Dichlor-benzoesaeure-methylester
methyl ester of 3,5-CBA
3,5-DICHLOROBENZOIC ACID METHYL ESTER
Methyl-3,5-dichlorobenzoate
Methyl 3,5-dichlorobenzoate
Benzoic acid,3,5-dichloro-,methyl ester
Density 1.355g/cm3
Boiling Point 273.4ºC at 760mmHg
Melting Point 56 °C
Molecular Formula C8H6Cl2O2
Molecular Weight 205.03800
Flash Point 118.1ºC
Exact Mass 203.97400
PSA 26.30000
LogP 2.78000
Vapour Pressure 0.00575mmHg at 25°C
Index of Refraction 1.545

SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifiers
Product name: METHYL 3,5-DICHLOROBENZOATE
REACH No.: A registration number is not available for this substance as the substance
or its uses are exempted from registration, the annual tonnage does not
require a registration or the registration is envisaged for a later
registration deadline.
CAS-No.: 2905-67-1


SECTION 2: Hazards identification
Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008
Acute toxicity, Oral (Category 3), H301
For the full text of the H-Statements mentioned in this Section, see Section 16.
Classification according to EU Directives 67/548/EEC or 1999/45/EC
Xn HarmfulR22
For the full text of the R-phrases mentioned in this Section, see Section 16.
Label elements
Labelling according Regulation (EC) No 1272/2008
Pictogram
Signal wordDanger
Hazard statement(s)
Toxic if swallowed.
Precautionary statement(s)
P301 + P310IF SWALLOWED: Immediately call a POISON CENTER or doctor/
physician.
Supplemental Hazardnone
Statements
Other hazards - none

SECTION 3: Composition/information on ingredients
Substances
Formula: C8H6Cl2O2
Molecular Weight: 205,04 g/mol
CAS-No.: 2905-67-1
Hazardous ingredients according to Regulation (EC) No 1272/2008
ComponentClassificationConcentration
METHYL 3,5-DICHLOROBENZOATE
Acute Tox. 3; H301-
For the full text of the H-Statements and R-Phrases mentioned in this Section, see Section 16

SECTION 4: First aid measures
Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in
section 11
Indication of any immediate medical attention and special treatment needed
no data available

SECTION 5: Firefighting measures
Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Carbon oxides, Hydrogen chloride gas
Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
no data available

SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
Wear respiratory protection. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure
adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.
For personal protection see section 8.
Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed
containers for disposal.
Reference to other sections
For disposal see section 13.

SECTION 7: Handling and storage
Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.
For precautions see section 2.2.
Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Specific end use(s)
A part from the uses mentioned in section 1.2 no other specific uses are stipulated

SECTION 8: Exposure controls/personal protection
Control parameters
Components with workplace control parameters
Exposure controls
Appropriate engineering controls
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling
the product.
Personal protective equipment
Eye/face protection
Face shield and safety glasses Use equipment for eye protection tested and approved under
appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and
the standard EN 374 derived from it.
Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle
respirator type N99 (US) or type P2 (EN 143) respirator cartridges as a backup to engineering
controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use
respirators and components tested and approved under appropriate government standards such
as NIOSH (US) or CEN (EU).
Control of environmental exposure
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

SECTION 9: Physical and chemical properties
Information on basic physical and chemical properties
a) AppearanceForm: solid
b) Odourno data available
c) Odour Thresholdno data available
d) pHno data available
e) Melting point/freezingno data available
point
f) Initial boiling point and no data available
boiling range
g) Flash pointno data available
h) Evapouration rateno data available
i) Flammability (solid, gas) no data available
j) Upper/lowerno data available
flammability or
explosive limits
k) Vapour pressureno data available
l) Vapour densityno data available
m) Relative densityno data available
n) Water solubilityno data available
o) Partition coefficient: n- log Pow: 3,383
octanol/water
p) Auto-ignitionno data available
temperature
q) Decompositionno data available
temperature
r) Viscosityno data available
s) Explosive propertiesno data available
t) Oxidizing propertiesno data available
Other safety information
no data available

SECTION 10: Stability and reactivity
Reactivity
no data available
Chemical stability
Stable under recommended storage conditions.
Possibility of hazardous reactions
no data available
Conditions to avoid
no data available
Incompatible materials
Strong oxidizing agents
Hazardous decomposition products
Other decomposition products - no data available
In the event of fire: see section 5

SECTION 11: Toxicological information
Information on toxicological effects
Acute toxicity
no data available
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitisation
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
IARC:No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Additional Information
RTECS: Not available
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.

SECTION 12: Ecological information
Toxicity
no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
Other adverse effects
no data available

SECTION 13: Disposal considerations
Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material
with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product.

SECTION 14: Transport information
UN number
ADR/RID: 2811IMDG: 2811IATA: 2811
UN proper shipping name
ADR/RID: TOXIC SOLID, ORGANIC, N.O.S. (METHYL 3,5-DICHLOROBENZOATE)
IMDG: TOXIC SOLID, ORGANIC, N.O.S. (METHYL 3,5-DICHLOROBENZOATE)
IATA:Toxic solid, organic, n.o.s. (METHYL 3,5-DICHLOROBENZOATE)
Transport hazard class(es)
ADR/RID: 6.1IMDG: 6.1IATA: 6.1
Packaging group
ADR/RID: IIIIMDG: IIIIATA: III
Environmental hazards
ADR/RID: noIMDG Marine pollutant: noIATA: no
Special precautions for user
no data available

SECTION 15: Regulatory information
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
Safety, health and environmental regulations/legislation specific for the substance or mixture
no data available
Chemical Safety Assessment


SECTION 16 - ADDITIONAL INFORMATION
N/A
Hazard Codes Xi
HS Code 2916399090

~79%

2905-67-1 structure

2905-67-1

Literature: Mineno, Tomoko; Sakai, Mai; Ubukata, Akira; Nakahara, Kazuhide; Yoshimitsu, Hitoshi; Kansui, Hisao Chemical and Pharmaceutical Bulletin, 2013 , vol. 61, # 8 p. 870 - 872

~64%

2905-67-1 structure

2905-67-1

Literature: Gassmann, Joerg; Voss, Juergen Zeitschrift fur Naturforschung - Section B Journal of Chemical Sciences, 2008 , vol. 63, # 11 p. 1291 - 1299

~%

2905-67-1 structure

2905-67-1

Literature: The Dow Chemical Company Patent: US4188346 A1, 1980 ;

~81%

2905-67-1 structure

2905-67-1

Literature: Niedan; Schoeler Chemosphere, 1997 , vol. 35, # 6 p. 1233 - 1241

~50%

2905-67-1 structure

2905-67-1

Literature: Niedan; Schoeler Chemosphere, 1997 , vol. 35, # 6 p. 1233 - 1241

~%

2905-67-1 structure

2905-67-1

Literature: Stempel et al. Journal of the American Chemical Society, 1951 , vol. 73, p. 455

~%

2905-67-1 structure

2905-67-1

Literature: Stempel et al. Journal of the American Chemical Society, 1951 , vol. 73, p. 455

~%

2905-67-1 structure

2905-67-1

Literature: Mueller; Tietz Chemische Berichte, 1941 , vol. 74, p. 807,821

~%

2905-67-1 structure

2905-67-1

Literature: MERCK and CO., INC. Patent: WO2005/97759 A1, 2005 ; Location in patent: Page/Page column 34-35 ; WO 2005/097759 A1
HS Code 2916399090
Summary 2916399090 other aromatic monocarboxylic acids, their anhydrides, halides, peroxides, peroxyacids and their derivatives VAT:17.0% Tax rebate rate:9.0% Supervision conditions:none MFN tariff:6.5% General tariff:30.0%