[Determination of alpha-naphthylacetic acid by high performance liquid chromatography].
Y P Li, H J Yang, C H Peng, X Y Zhang
Index: Se Pu 18(4) , 372-3, (2000)
Full Text: HTML
Abstract
A high performance liquid chromatographic method for the determination of alpha-naphthylacetic acid has been established on a Hypersil C18 column(4.6 mm i.d. x 250 mm, 5 microns), with the mobile phase of methanol-water-phosphoric acid(60:40:0.35, V/V), and UV detection at 272 nm. The linear correlation was observed within the range of 16 mg/L-1,000 mg/L(r = 0.9997). The RSD was 0.8%(n = 5). The method is simple and accurate.
Related Compounds
Related Articles:
2014-10-13
[Biomacromolecules 15(10) , 3559-68, (2014)]
1993-06-01
[Chem. Biol. Interact. 87(1-3) , 77-83, (1993)]
2015-06-01
[Leuk. Lymphoma 56 , 1863-8, (2015)]
2011-11-01
[Cell Biol. Int. 35(11) , 1111-9, (2011)]
1988-01-01
[Drug Metab. Dispos. 16(4) , 627-34, (1988)]