Metrological traceability in mass spectrometry-based targeted protein quantitation: a proof-of-principle study for serum apolipoproteins A-I and B100.
Nico P M Smit, Fred P H T M Romijn, Irene van den Broek, Jan W Drijfhout, Martin Haex, Arnoud van der Laarse, Yuri E M van der Burgt, Christa M Cobbaert
文献索引:J. Proteomics 109 , 143-61, (2014)
全文:HTML全文
摘要
In this study, we have followed up on previous liquid chromatography (LC) multiple reaction monitoring (MRM) mass spectrometry (MS) approaches for measurement of apolipoprotein (apo) A-I and apo B100 in serum aiming for implementation of a multiplexed assay in a clinical chemistry laboratory with full metrological traceability. Signature peptides were selected and detected by dynamic MRM, and stable isotope labeled (SIL)-peptides were used as internal standards. Five apo A-I and four apo B100 peptides were measured in serum digests with linearity (R(2)>0.992) in the physiologically relevant concentration ranges. Linearity with regard to protein concentration was ascertained at five concentration levels (R(2)>0.926 and R(2)>0.965, for the apo A-I and apo B100 peptides, respectively). Three native value-assigned sera were used as external calibrators for further method verification. Imprecision values on sample preparation and LC-MS/MS acquisition were below the established minimal specifications for apo A-I and apo B100 (5.0% and 5.3%, respectively). Correlation of LC-MS/MS results with immunoturbidimetric assay results, for normo- and hypertriglyceridemic samples, showed R(2)>0.944 for apo A-I and R(2)>0.964 for apo B100. This LC-MS/MS method has potential for clinical application in normo- and dyslipidemic patients.Measurement of apo A-I and apo B100 may offer an alternative to high and low density lipoprotein cholesterol (HDL-c and LDL-c) methods for cardiovascular disease risk assessment in dyslipidemic patients [1]. An LC-MS/MS method for apo A-I and apo B100 has the advantage of antibody independent and specific detection of protein signature peptides. The introduction of an LC-MS/MS method for apo A-I and apo B100 can serve as an example for many existing and newly developed (multiplex) biomarker methods in quantitative clinical chemistry proteomics (qCCP). Such LC-MS/MS methods should meet basic clinical chemistry principles with regard to test evaluation [2]. Criteria for imprecision should be pre-defined, e.g., based on biological variation. The use of commutable and traceable serum-based calibrators will improve inter-laboratory reproducibility of LC-MS/MS methods and may contribute to a more rapid transition of biomarker discovery to clinical utility with benefit for the patient treatment and improvement of general health care.Copyright © 2014 Elsevier B.V. All rights reserved.
相关化合物
相关文献:
2015-01-15
[J. Ethnopharmacol. 159 , 93-101, (2014)]
2014-11-01
[J. Am. Soc. Mass Spectrom. 25(11) , 1897-907, (2014)]
2014-12-01
[Biochim. Biophys. Acta 1842(12 Pt A) , 2345-56, (2014)]
2015-02-13
[J. Chromatogr. A. 1381 , 54-63, (2015)]
2014-12-30
[Proc. Natl. Acad. Sci. U. S. A. 111(52) , 18709-14, (2014)]