Journal of chromatography. A 2014-11-28

Separations of substituted benzenes and polycyclic aromatic hydrocarbons using normal- and reverse-phase high performance liquid chromatography with UiO-66 as the stationary phase.

Wei-Wei Zhao, Chao-Yan Zhang, Zeng-Guang Yan, Li-Ping Bai, Xiayan Wang, Hongliang Huang, You-Ya Zhou, Yabo Xie, Fa-Sheng Li, Jian-Rong Li

文献索引:J. Chromatogr. A. 1370 , 121-8, (2014)

全文:HTML全文

摘要

Metal-organic frameworks (MOFs) have great potential for applications in chromatography due to their highly tailorable porous structures and unique properties. In this work, the stable MOF UiO-66 was evaluated as both a normal-phase (NP-) and a reverse-phase (RP-) stationary phase in the high performance liquid chromatography (HPLC) to separate substituted benzenes (SBs) and polycyclic aromatic hydrocarbons (PAHs). It was found that the mobile phase composition has a significant effect on the HPLC separation. Baseline RP-HPLC separations of xylene isomers; naphthalene and anthracene; naphthalene and chrysene; and naphthalene, fluorene, and chrysene were achieved using MeOH/H2O ratios of 80:20, 75:25, 85:15, and 75:25, respectively, on the UiO-66 column. Similarly, baseline NP-HPLC separations of xylene isomers and ethylbenzene; ethylbenzene, styrene, o-xylene, and m-xylene; and several PAHs were also obtained on the UiO-66 column with different mobile phase compositions. The relative standard deviations (RSDs) of retention time, peak height, peak area, and half peak width for five replicate separations of the tested analytes were within the ranges 0.2-0.4%, 0.2-1.6%, 0.7-3.9%, 0.4-1.1%, respectively. We also evaluated other critical HPLC parameters, including injected sample mass, column temperature, and the thermodynamic characters of both the RP-HPLC and the NP-HPLC separation processes. It was confirmed that the separation of SBs on a UiO-66 column was an exothermic process, controlled by both enthalpy change (ΔH) and entropy change (ΔS). The reverse shape selectivity, size selectivity, stacking effect, and electrostatic force played vital roles in the separations of these analytes. To the best of our knowledge, this method is one of the very few examples of using MOFs as the stationary phase in both NP-HPLC and RP-HPLC. MOF-based stationary phases may thus be applied in the separations and analyses of SBs and PAHs in environmental samples. Copyright © 2014 Elsevier B.V. All rights reserved.


相关化合物

  • 盐酸
  • 乙醇
  • 正己烷
  • 对二甲苯
  • N,N-二甲基甲酰胺
  • 间二甲苯
  • 乙苯

相关文献:

Aptamer-based polyvalent ligands for regulated cell attachment on the hydrogel surface.

2015-04-13

[Biomacromolecules 16(4) , 1382-9, (2015)]

Assembly and structure of Lys33-linked polyubiquitin reveals distinct conformations.

2015-04-15

[Biochem. J. 467(2) , 345-52, (2015)]

Small-molecule inhibitors of ERK-mediated immediate early gene expression and proliferation of melanoma cells expressing mutated BRaf.

2015-05-01

[Biochem. J. 467(3) , 425-38, (2015)]

Fine mapping and characterization of the L-polymerase-binding domain of the respiratory syncytial virus phosphoprotein.

2015-04-01

[J. Virol. 89(8) , 4421-33, (2015)]

DNase II-dependent DNA digestion is required for DNA sensing by TLR9.

2015-01-01

[Nat. Commun. 6 , 5853, (2015)]

更多文献...