偏硼酸锂,无水

偏硼酸锂,无水结构式
偏硼酸锂,无水结构式
品牌特惠专场
常用名 偏硼酸锂,无水 英文名 Lithium metaborate
CAS号 13453-69-5 分子量 50.75870
密度 1,4 g/cm3 沸点 N/A
分子式 BHLiO2 熔点 845 °C(lit.)
MSDS 中文版 美版 闪点 N/A

X-ray diffraction, spectroscopic and thermal studies on a potential semiorganic NLO material: lithium bis-L-malato borate.

Spectrochim. Acta. A. Mol. Biomol. Spectrosc. 61(8) , 1777-82, (2005)

A semiorganic nonlinear optical material, lithium bis-L-malato borate (LBMB) (molecular formula C8H8BLiO10), has been synthesized, and single crystals grown from an aqueous solution, by the method of slow evaporation at 30 degrees C. Crystals of size up to 7 ...

Greenlight: from potassium-titanyl-phosphate to lithium triborate or from good to better?

Curr. Opin. Urol. 21(1) , 27-30, (2011)

To report on the latest data in the recent literature regarding the so-called 'Greenlight laser vaporization of the prostate'. Specifically to comment on the evolution of the 80-W KTP (potassium-titanyl-phosphate) system to the more recent 120-W LBO (lithium ...

Comparative study of LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P TL detectors.

Radiat. Prot. Dosimetry 119(1-4) , 191-6, (2006)

Recently, two new types of 'tissue equivalent' thermoluminescent detectors (TLDs) have aroused attention: LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P. In this work the characteristics of both detectors were compared with the characteristics of the well-known type LiF...

Optical studies on electron beam evaporated lithium triborate films.

Spectrochim. Acta. A. Mol. Biomol. Spectrosc. 96 , 805-8, (2012)

Lithium triborate (LB3) has numerous applications in scintillator for neutron detection, laser weapon and communication. LB3 films have been prepared by electron beam evaporation technique under a pressure of 1×10(-5) mbar on glass substrate at 323 K for 4 mi...

Experimental study of the generation of a blue laser by intracavity frequency doubling of a cw Nd:GdVO4 laser with lithium borate.

Appl. Opt. 48(16) , 2979-82, (2009)

Efficient cw intracavity frequency doubling of a diode end-pumped Nd:GdVO4 laser that operates in the 4F(3/2) --> 4I(9/2) transition at 912 nm is demonstrated. A 15 mm long lithium borate crystal, cut for critical type I phase matching at room temperature, wa...

Thermal, structural, optical, and dielectric properties of (100 - x)Li2B4O7 - x(BaO-Bi2O3-Nb2O5) glasses and glass-nanocrystal composites.

J. Nanosci. Nanotechnol. 7(3) , 1006-13, (2007)

Transparent glasses in the system (100 - x)Li2B4O7 - x(BaO-Bi2O3-Nb2O5) (x = 10, 20, and 30) were fabricated via the conventional melt-quenching technique. The amorphous and glassy characteristics of the as-quenched samples were established by the differentia...

Phase evolution, characterization, and impedance spectroscopic analysis of nanocrystalline SrBi2Nb2O9 in glassy Li2B4O7 matrix.

J. Nanosci. Nanotechnol. 1(4) , 425-32, (2001)

Transparent glass composites in the system (100 - x) Li2B4O7 - x SrBi2Nb2O9 (where x = 5, 10, 15, 20, 25, and 30, in molar ratio) were fabricated by conventional melt-quenching technique. The amorphous nature of the as-quenched glass composites was confirmed ...

A method to build an analytic model of the 10B(n,alpha)7Li reaction rate space distribution for boron neutron capture therapy (BNCT).

Appl. Radiat. Isot. 67(7-8 Suppl) , S149-52, (2009)

This work provides the basis of a methodology to build a deterministic model for the spatial distribution of the (10)B(n,alpha)(7)Li reaction rate in boron neutron capture therapy (BNCT), as a function of space variables, boron concentration and beam incidenc...

High resolution emission spectra of TL materials.

Radiat. Prot. Dosimetry 100(1-4) , 211-6, (2002)

High resolution emission spectra of several TL materials, that are commonly used in dosimetry, were measured using a low cost fibre optic spectrometer containing a 2048 pixel CCD array. The spectra were taken from 177 to 890 nm with a wavelength resolution of...

A comparative study of the responses of lithium borate and calcium sulphate phosphors in a TL personal dosemeter.

Radiat. Prot. Dosimetry 144(1-4) , 262-5, (2011)

This work summarises the results of a series of experiences made on Panasonic UD-802AS, a multi-element dosemeter that is currently used in Caorso Nuclear Power Plant for personnel external monitoring. Two main topics have been considered: energy response and...