![]() 二辛基苯基膦酸酯结构式
![]() |
常用名 | 二辛基苯基膦酸酯 | 英文名 | Phosphonic acid,P-phenyl-, dioctyl ester |
---|---|---|---|---|
CAS号 | 1754-47-8 | 分子量 | 382.51700 | |
密度 | 0.967 g/mL at 25 °C(lit.) | 沸点 | 207 °C4 mm Hg(lit.) | |
分子式 | C22H39O3P | 熔点 | N/A | |
MSDS | 中文版 美版 | 闪点 | >230 °F |
A novel approach for honey pollen profile assessment using an electronic tongue and chemometric tools.
Anal. Chim. Acta 900 , 36-45, (2015) Nowadays the main honey producing countries require accurate labeling of honey before commercialization, including floral classification. Traditionally, this classification is made by melissopalynology analysis, an accurate but time-consuming task requiring l... |
|
Ionophore-based potentiometric sensors for the flow-injection determination of promethazine hydrochloride in pharmaceutical formulations and human urine.
Sensors (Basel.) 11(1) , 1028-42, (2011) Plasticised poly(vinyl chloride)-based membranes containing the ionophores (α-, β- and γ-cyclodextrins (CD), dibenzo-18-crown-6 (DB18C6) and dibenzo-30-crown-10 (DB30C10) were evaluated for their potentiometric response towards promethazine (PM) in a flow inj... |
|
Amodiaquine polymeric membrane electrode.
J. Pharm. Biomed. Anal. 41(1) , 70-6, (2006) The construction and electrochemical response characteristics of two types of poly(vinyl chloride) (PVC) membrane sensors for the determination of amodiaquine hydrochloride (ADQ.2HCl) are described. The sensing membrane comprised an ion-pair formed between th... |
|
PVC membrane based potentiometric sensors for uranium determination.
Talanta 54(6) , 1153-61, (2001) Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. ... |
|
Study of sweet taste evaluation using taste sensor with lipid/polymer membranes.
Biosens. Bioelectron. 19(12) , 1559-63, (2004) The higher sensitivity for sweeteners can be achieved by newly developed lipid/polymer membranes. The membrane is composed of lipids such as phosphoric acid di-n-hexadecyl ester and tetradodecylammoniumbromid, and a plasticizer, dioctyl phenylphosphonate. As ... |
|
Theory of electric characteristics of the lipid/PVC/DOPP membrane and PVC/DOPP membrane in response to taste stimuli.
Biophys. Chem. 61(1) , 29-35, (1996) Electric characteristics of two kinds of membranes in response to NaCl and quinine were theoretically studied; one membrane composed of polyvinyl chloride (PVC) and dioctylphenylphosphonate (DOPP), and the other a lipid/PVC/DOPP membrane containing PVC, DOPP ... |
|
Extended sensitivity for the calcium selective electrode.
Anal. Biochem. 157 , 345, (1986) Sensitivity of calcium-selective electrodes heretofore has been limited to calcium concentrations above 10(-8) M in the absence of competing ions. We describe the use of calcium buffers to stabilize the free calcium in the reference electrode. Electrode calib... |
|
Iron ion sensor based on functionalized ZnO nanorods. Kimkeang K, et.al.
Electroanalysis 24 (3) , 521-528, (2012)
|
|
Raman and UV-vis spectroscopic study of polyaniline membranes containing a bulky cationic additive. Lindfors T
J. Electroanal. Chem. 518 (2) , 131-138, (2002)
|
|
G.J. Moody, J.D.R. Thomas
Ion-Selective Electrode Rev. 1 , 3, (1979)
|