金胺O结构式
|
常用名 | 金胺O | 英文名 | Auramine O |
---|---|---|---|---|
CAS号 | 2465-27-2 | 分子量 | 303.830 | |
密度 | 1.01g/cm3 | 沸点 | 406.2ºC at 760mmHg | |
分子式 | C17H22ClN3 | 熔点 | >250 °C (dec.)(lit.) | |
MSDS | 中文版 美版 | 闪点 | 199.4ºC | |
符号 |
GHS06, GHS08 |
信号词 | Danger |
Functional and genetic characterization of the tap efflux pump in Mycobacterium bovis BCG.
Antimicrob. Agents Chemother. 56(4) , 2074-83, (2012) Efflux pumps extrude a wide variety of chemically unrelated compounds conferring multidrug resistance and participating in numerous physiological processes. Mycobacterium tuberculosis possesses many efflux pumps, and their roles in drug resistance and physiol... |
|
Confocal laser scanning microscopy elucidation of the micromorphology of the leaf cuticle and analysis of its chemical composition.
Protoplasma 252 , 1475-86, (2015) Electron microscopy techniques such as transmission electron microscopy (TEM) and scanning electron microscopy (SEM) have been invaluable tools for the study of the micromorphology of plant cuticles. However, for electron microscopy, the preparation technique... |
|
Efficacy of real-time polymerase chain reaction for rapid diagnosis of endobronchial tuberculosis
Int. J. Infect. Dis. 27 , 13-7, (2014) • We assess the efficacy of realtime PCR of bronchial biopsies for diagnosis of EBTB • Real-time PCR yields better than AFB staining of bronchial brushing or sputum smear • Bronchoscopic types of EBTB influence the diagnostic yield of real time PCR |
|
Analysis and testing of biological stains--the Biological Stain Commission Procedures.
Biotech. Histochem. 77(5&6) , 237-275, (2002)
|
|
A prospective evaluation of selection criteria for the use of Nucleic Acid Amplification Techniques to test for the presence of Mycobacterium tuberculosis in respiratory tract samples.
Clin. Lab. 55(11-12) , 441-6, (2009) Although Mycobacterium tuberculosis (MTB) can be detected rapidly by means of Nucleic Acid Amplification Techniques (NAT), these NAT tests are expensive and therefore are not used in routine practice or as a screening tool.Although it is generally accepted th... |
|
The case of the disappearing mycobacteria in Ziehl-Neelsen-stained smears.
Int. J. Infect. Dis. 15(4) , e291, (2011)
|
|
Auramine-O as a fluorescence marker for the detection of amyloid fibrils.
J. Phys. Chem. B 116(45) , 13389-95, (2012) There is an indispensable need for a fluorescence marker for the detection of amyloid fibrils, where, at present, the most used marker is thioflavin-T (ThT). Here, we present the use of auramine-O (AuO) as a possible alternative to ThT. As with ThT, the incre... |
|
Reactive dynamics in confined liquids: ultrafast torsional dynamics of auramine O in nanoconfined water in aerosol OT reverse micelles.
J. Phys. Chem. B 113(6) , 1623-31, (2009) The effects of confinement on the ultrafast torsional reaction of auramine O in aqueous solution are investigated through ultrafast fluorescence up-conversion with 50 fs time resolution. The aqueous solution is confined in nanoscale water droplets by an ionic... |
|
The CyScope® fluorescence microscope, a reliable tool for tuberculosis diagnosis in resource-limited settings.
Am. J. Trop. Med. Hyg. 83(4) , 906-8, (2010) Poor laboratory equipment and few human resources have made it difficult to implement microscopic diagnosis of pulmonary tuberculosis (TB) on a large scale basis worldwide. Three hundred sputum samples from patients in Cameroon were studied by using the CySco... |
|
Light-emitting diode with various sputum smear preparation techniques to diagnose tuberculosis.
Int. J. Tuberc. Lung Dis. 16(3) , 402-7, (2012) Mawenzi Regional Hospital, northern Tanzania.To determine the value of light-emitting diode (LED) microscopy in diagnosing tuberculosis (TB) on bleach-treated and direct sputum smears.Sputum samples were collected from patients suspected of pulmonary TB who p... |