常用名 反-1,2-环己烷二甲酸 英文名 Lura
CAS号 2305-32-0 分子量 172.178
密度 1.3±0.1 g/cm3 沸点 384.1±35.0 °C at 760 mmHg
分子式 C8H12O4 熔点 228-230 °C(lit.)
MSDS 中文版 美版 闪点 200.3±22.4 °C
符号 GHS07
GHS07
信号词 Warning

Determination of hexahydrophthalic acid and methylhexahydrophthalic acid in plasma after derivatisation with pentafluorobenzyl bromide using gas chromatography and mass spectrometric detection.

J. Chromatogr. B. Biomed. Sci. Appl. 691(2) , 331-9, (1997)

A method for the simultaneous determination of hexahydrophthalic acid (HHP acid) and methylhexahydrophthalic acid (MHHP acid) in human plasma was developed. The procedure was a rapid, single step extractive derivatisation with pentafluorobenzyl bromide as the...

Toxicokinetics and biological monitoring in experimental exposure of humans to gaseous hexahydrophthalic anhydride.

Scand. J. Work. Environ. Health 19(3) , 183-90, (1993)

Six healthy volunteers were exposed to gaseous hexahydrophthalic anhydride (HHPA) concentrations of 10, 40, or 80 micrograms.m-3 (65, 260 or 520 nmol.m-3, respectively) for 8 h. The respiratory uptake of the inhaled HHPA was almost complete. Rapid increases i...

Method for the biological monitoring of hexahydrophthalic anhydride by the determination of hexahydrophthalic acid in urine using gas chromatography and selected-ion monitoring.

J. Chromatogr. A. 572(1-2) , 117-31, (1991)

A method for the determination of hexahydrophthalic acid, a metabolite of hexahydrophthalic anhydride, in human urine has been developed. The urine was worked-up by liquid-solid extraction, esterified with boron trifluoride-methanol, and analysed by capillary...

Generation of hexahydrophthalic anhydride atmospheres in a controlled human-use test chamber.

Am. Ind. Hyg. Assoc. J. 55(4) , 330-8, (1994)

A method for generating controlled atmospheres of hexahydrophthalic anhydride (HHPA) in an 8 m3 exposure chamber was developed. The permeation principle was used for gaseous HHPA generation. HHPA concentration was monitored by sampling on XAD-2 tubes and by a...

Occupational exposure to hexahydrophthalic anhydride: air analysis, percutaneous absorption, and biological monitoring.

Int. Arch. Occup. Environ. Health 65(1) , 43-7, (1993)

Urinary hexahydrophthalic acid (HHP acid) levels were determined in 20 workers occupationally exposed to hexahydrophthalic anhydride (HHPA) air levels of 11-220 micrograms/m3. The levels of HHP acid in urine increased rapidly during exposure and the decreases...

Methods for the identification of chemical respiratory allergens in rodents: comparisons of cytokine profiling with induced changes in serum IgE.

J. Appl. Toxicol. 23(4) , 199-207, (2003)

No validated or widely recognized test methods are currently available for the prospective identification of chemicals with the potential to cause respiratory allergy. The cellular and molecular mechanisms that result in the induction of chemical sensitizatio...

Risk factors for immunologically mediated disease in workers with respiratory symptoms when exposed to hexahydrophthalic anhydride.

J. Lab. Clin. Med. 127(5) , 443-7, (1996)

Occupational immunologic lung diseases caused by exposures to substances such as hexahydrophthalic anhydride are significant health problems. It would be useful to identify risk factors, other than exposure, for occupational immunologic lung diseases such as ...