indium tin oxide

indium tin oxide Structure
indium tin oxide structure
Common Name indium tin oxide
CAS Number 50926-11-9 Molecular Weight 428.33400
Density 1.2 g/mL at 25 °C(lit.) Boiling Point 82 °C
Molecular Formula In2O5Sn Melting Point Approximately 1500ºC
MSDS Chinese USA Flash Point 57.2 °F
Symbol GHS02 GHS07
GHS02, GHS07
Signal Word Danger

Effects of potassium on the supramolecular structure and electronic properties of eumelanin thin films.

Langmuir 26(24) , 19007-13, (2010)

The role of potassium in the formation of synthetic eumelanin aggregates is investigated by atomic force microscopy and soft-X-ray spectroscopy. Control over the thin film granularity is achieved by using K salts, in both drop casting and electrodeposition of...

Novel regulation of cardiac metabolism and homeostasis by the adrenomedullin-receptor activity-modifying protein 2 system.

Hypertension 61(2) , 341-51, (2013)

Adrenomedullin (AM) was identified as a vasodilating and hypotensive peptide mainly produced by the cardiovascular system. The AM receptor calcitonin receptor-like receptor associates with receptor activity-modifying protein (RAMP), one of the subtypes of reg...

Electric-field triggered controlled release of bioactive volatiles from imine-based liquid crystalline phases.

Chemistry 15(1) , 117-24, (2009)

Application of an electric field to liquid crystalline film forming imines with negative dielectric anisotropy, such as N-(4-methoxybenzylidene)-4-butylaniline (MBBA, 1), results in the expulsion of compounds that do not participate in the formation of the li...

A cantilever-free approach to dot-matrix nanoprinting.

Proc. Natl. Acad. Sci. U. S. A. 110(32) , 12921-12924, (2013)

Scanning probe lithography (SPL) is a promising candidate approach for desktop nanofabrication, but trade-offs in throughput, cost, and resolution have limited its application. The recent development of cantilever-free scanning probe arrays has allowed resear...

Paradoxical ATP elevation in ischemic penumbra revealed by quantitative imaging mass spectrometry.

Antioxid. Redox Signal. 13(8) , 1157-1167, (2010)

Local responses of energy metabolism during brain ischemia are too heterogeneous to decipher redox distribution between anoxic core and adjacent salvageable regions such as penumbra. Imaging mass spectrometry combined by capillary electrophoresis/mass spectro...

Online coupling of digital microfluidic devices with mass spectrometry detection using an eductor with electrospray ionization. Baker CA and Roper MG

Anal. Chem. , 2955-2960, (2012)

High-resolution frequency-modulation atomic force microscopy in liquids using electrostatic excitation method. Umeda K, et al.

Appl. Phys. Express 3(6) , 065205, (2010)

Preparation of non-annealed anatase TiO< sub> 2</sub> film on ITO substrate by anodizing in hot phosphate/glycerol electrolyte for dye-sensitized solar cells. Tsuji E, et al.

Mater. Lett. 91 , 39-41, (2013)

Optical Fiber Refractometers based on Indium Tin Oxide Coatings with Response in the Visible Spectral Region Zamarreno CR, et al.

Procedia Eng. 25 , 499-502, (2011)

Shigesato, Y.; Takaki, S.; Haranoh, T.

J. Appl. Phys. 71 , 3356, (1992)